Hunan Sundy Science And Technology Development Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Zuo Judy
  • Company Name : Hunan Sundy Science And Technology Development Co., Ltd.
  • Tel : 86-731-88112150
  • Fax : 86-731-88134650
  • Address : Hunan,Chang Sha,Crossing of Lujing Road and West Xianjiahu Road, Lugu
  • Country/Region : China
  • Zip : 410205

High Speed Bomb Calorimeter SDC313

High Speed Bomb Calorimeter SDC313
Product Detailed
Fast test speed Strong environmental adaptability Convenient data processing Accurate and reliable Conformity with ASTMD5865

Bomb Calorimeter SDC313

Applicable Scope:

SDC Series Calorimeters are applicable to measure the calorific value of coal, coke, petroleum, cement black meal and other combustibles.

Applicable standards

ASTM D 5865-2007a     Standard Test Method for Gross Calorific Value of Coal and Coke

GB/T213-2008               Determination of calorific value of coal

  

Standard layout: SDC311 mainframe, dedicated water tank, Lenovo computer, Laser printer

Technical parameter:    

Single Complete Testing Duration

<13 min

Precision

RSD≤0.1%

Stability

Heat Capacity Variation in 3 months≤0.20 %

Ambient Temperature

The test results confirm to demands when temperature  during

(10-30)oC

Accuracy

The mean value and standard value deviation is less than 50J/g after 5 caloric value tests of benzoic acid.

Max Test Range

42000J/g

Temperature Resolution

0.0001 K

Sample Weight

0.5-1.5g

the Water Weight of External Barrel

40kg

New type of Oxygen Bomb

Yes

Oxygen Bomb Identification

Automatic

CAN Bus Interface

Yes

Self-diagnostic Function

Yes

Complete Appliance Crust Shaped

Yes

Max Power

1.5kW

Voltage

AC220±10% 50Hz±1Hz

Mainframe Size

432×560×393mm

Net Weight

60kg

Main Features :Fast testing speed , large increase of the testing efficiency , the complete testing duration < 13min, the single equipment testing 4~5 times /h.All measured data is real and reliable , without the use of the software correction to change the testing results . Highly environment adaptable, the air flow and fluctuation of the ambient temperature( e.g. whether it is close to the heat source , large fluctuation of the ambient temperature, etc) will not affect the accuracy and stability of the test.  Compact size and structure , attractive appearance,  with  the use of quite a lot mould making and smallest test table-board is required .   Simple erection and debugging, with no external hardware control or complicated mechanical components so as to ensure stable operation of the instrument . New type of oxygen bomb, automatic identification of the oxygen bomb, automatic utilization of the built-in volume measurement unit to fix the inner barrel water volume , automatic control of the water temperature of the inner and external barrels, automatic implementation of the whole test process.   Application of the advanced communication control technique. The CAN bus interface realized multiple control with one computer ,  and the inter-testing activity will not affect each other ( different models and different kinds of the equipment ).