High Speed Automatic Calorimeter SDC5015
Applicable Scope:
SDC Series Calorimeters are applicable to measure the calorific value of coal, coke, petroleum, cement black meal and other combustibles.
Conformance with Standards:
ASTM D 5865-2007a Standard Test Method for Gross Calorific Value of Coal and Coke
GB/T213-2008 Determination of calorific value of coal
Standard layout:
SDC5015 mainframe, Special water tank, Lenovo computer, Laser printer
Technical parameter:
Single Complete Testing Duration | <15min | Precision | RSD≤0.1% |
Stability | Heat Capacity Variation in 3 months≤0.20 % | Ambient Temperature | The test results confirm to demands when temperature during(10-30oC) |
Accuracy | The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. | Max Test Range | 42000J/g |
Temperature Resolution | 0.0001 K | Sample Weight | 0.5-1.5g |
the Water Weight of Water Tank | 40kg | New type of Oxygen Bomb | Yes |
Oxygen Bomb Identification | Automatic | CAN Bus Interface | Yes |
Self-diagnostic Function | Yes | Complete Appliance Crust Shaped | No |
Max Power | 1.5kW | Voltage | AC220±10% 50Hz±1Hz |
Mainframe Size | 440×565×400mm | Net Weight | 63kg |
Main Features:
The test results are fast, accurate and steady, and will not be affected by fluctuation of the ambient temperature.
1. All measured data are real and reliable with no software correction.
2. Highly automated instrument; can automatically recognize oxygen bomb, guarantee the quality of water, control temperature and carry out the test.
3. Strong adaptive capacity to environment; the testing results will not be affected by the fluctuation of the ambient temperature.
4. The isothermal points with helix tube technology (patent number 200610031417.X,200610031414.6) realized temperature consensus of every part of the jacket and barrelhead quickly, temperature of any fixed point can exactly represent that of the jacket and barrelhead, making sure the test results are accurate.
5. The application of power contravariance and purification technology makes sure the instrument will not be affected by large variation of power voltage or power frequency.
6. Simple installation and debugging, easy to control.
7. Multiply controlled by one computer and the inter-testing activity will not interplay.
8. Data processing works in parallel with testing; easy for the users to look up test data.
9. Networking and the balance interlocking are supportive.
Presentation in Indonesia
High Speed Automatic Calorimeter SDC5015